          16. BATTERY/CHARGING SYSTEM                                               GRAND DINK 125/150


                                                  A.C. Generator Stator          Pulser Coil
 A.C. GENERATOR REMOVAL
 A.C. generator removal ( 10-3)
 A.C. generator installation ( 10-6)




                                                  Right Crankcase Cover           Bolts

 REGULATOR/RECTIFIER
 INSPECTION
 Remove the frame front cover. ( 2-5)
 Remove the regulator/rectifier wire coupler.
 Check the continuity between the wire
 terminals.
 Normal Direction: Continuity
                 (+) Probe       (-) Probe
        I         Yellow           Green
       II        Red/Black        Yellow                           Regulator/Rectifier

 Reverse Direction: No Continuity                Normal                    Red/Black
                  (+) Probe     (-) Probe        Direction
        I           Green        Yellow
                                                       Yellow




       II          Yellow       Red/Black



                                                                                       Reverse
                                                                Green                  Direction



 VOLTAGE REGULATION TEST
 Connect a voltmeter across the battery                                      Black
 terminals.
 Start the engine and gradually increase the
 engine speed.
 The battery terminal voltage should be within
 14.015.0V.


                                                                Voltage Sensor



                                                                                          16-6