grand dink 125 mmc 1 Werkstatthandbuch : Seite 244

Microfiches
Image preview

Seite 242

Image preview

Seite 243

Image preview

Seite 245

Image preview

Seite 246

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 249
          20. EXHAUST EMISSION CONTROL
    SYSTEM                                                           GRAND DINK 125/150

 TROUBLESHOOTING
 High CO at idle speed
 1. Damaged or clogged reed valve
 2. Damaged or clogged air injection cut-off valve
 3. Clogged air cleaner

 Backfiring at sudden deceleration
 1. Damaged reed valve (malfunction)
 2. Faulty air injection cut-off valve (unable to close)
 3. Carburetor incorrectly adjusted
 4. Faulty air cut-off valve
 5. Leaking vacuum tube

 Exhaust muffler noise
 1. Faulty air injection cut-off valve
 2. Broken vacuum tube
 3. Faulty reed valve




 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
 · During operation, be careful to avoid scalding caused by the exhaust muffler.
 · Note the locations of tubes for proper installation.
 · Replace any damaged tube with a new one.
 · Make sure to tighten the connector of each tube securely

 TOOLS
 · Vacuum pump


 SPECIFICATIONS
 Air injection cut-off valve actuating pressure
 ~~250mm/Hg~~30 liter/min.
 Reed valve stopper clearance4.6mm




20-2