          18. STARTING SYSTEM                                                     GRAND DINK 125/150



 STARTER RELAY INSPECTION
 Disconnect the starter relay wire connector.
 Check for continuity between the yellow/red
 wire terminal and ground.
 There should be continuity when the starter
 button is depressed.
 If there is no continuity, check the starter
 button for continuity and inspect the wire.



                                                    Yellow/Red Wire
                                                                      Starter Relay
 OPERATION TEST
 Connect the electric tester to the starter relay
 larger terminals that connect to the battery
 positive cable and the starter motor cable.
 Connect a fully charged battery across the
 starter relay yellow/red and green/yellow
 wire terminals.
 Check for continuity between the starter relay
 large terminals. The relay is normal if there is
 continuity.




                                                                                      18-6