          9. DRIVE AND DRIVEN PULLEYS                                             ATV 300/250

                                                       Bolts          Starting Cover
 LEFT CRANKCASE COVER
 REMOVAL
 Remove the five bolts.
 Remove the starting cover.




                                                                Gasket
 Remove the dowel pins and gasket.




                                                         Dowel Pins

                                                                 Outlet Hose Cover
 Remove the three bolts.
 Remove the outlet hose cover.




                                                                Bolts

                                                   Inlet Hose       Outlet Hose
 Loosen the drive belt air inlet and outlet hose
 band screws and disconnect them from the
 left crankcase cover.




                                                         Screws

9-3