          16. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                ATV 300/250


 CHARGING SYSTEM
 SHORT CIRCUIT TEST
 Disconnect the ground wire from the battery
 and connect an ammeter across the battery
 negative (-) terminal and the ground wire.
 Turn the ignition switch OFF and check for
 short circuit.
 Connect the electric tester positive (+)
    terminal to ground wire and the tester
    negative (-) terminal to the battery
    negative (-) terminal.
 If any abnormality is found, check the
 ignition switch and wire harness for short
 circuit.


 CURRENT TEST
 This inspection must be performed with an
 electric tester when the battery is fully
 charged.
 Warm up the engine for inspection.
 Connect the electric tester across the battery
 terminals. Disconnect the red wire from the
 fuse terminal and connect an ammeter
 between the red wire lead and the fuse
 terminal as shown.
 Attach a tachometer to the engine.
 Start the engine and gradually increase the
 engine speed to measure the limit voltage
 and current.
 Limit Voltage/Current:
                     13.515.5 V/0.5 A max.
 If the limit voltage is not within the
 specified range, check the
 regulator/rectifier.




                                                      16-6