          16. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                               ATV 300/250


 A.C. GENERATOR INSPECTION
 This test can be made without removing
   the stator from the engine.
 Disconnect the A.C. generator connector.
 Check the continuity between the yellow
 wires and ground.
 There should be continuity between the
 yellow wires and no continuity between
 each yellow wire and ground.
 Resistance (at 20°C):
   YellowYellow              1.62.5 


 A.C. GENERATOR/FLYWHEEL                       A.C. Generator    Bolts             Set Plate
 REMOVAL
 Remove the right crankcase cover. (Refer to
 the "WATER PUMP SHAFT REMOVAL"
 section in the chapter 12)

 Remove the pulser coil screws and then
 remove the A.C. generator wire set plate.
 Remove the A.C. generator bolts and then
 remove A.C. generator and pulser coil from
 right crankcase cover.
                                               Pulser Coil              Screws

   When removing the pulser coil and
   stator, be careful not to damage them to
   avoid shorted or broken wire.


 Remove the oil through guide and spring.




                                                     Oil Through Guide            Spring
                                                 Flywheel Holder
 Hold the flywheel with a flywheel holder
 and remove flywheel nut and wash.

 Special tool:
 Flywheel holder    E021




                                                             Flywheel            Nut
                                                                                       16-8