          3. INSPECTION/ADJUSTMENT                                                ATV 300/250


 CLEAN AIR FILTER ELEMENT
 Wash the element gently, but throughly in
 solvent.
 Use parts cleaning solvent only. Never
   use gasoline or low flash point solvents
   which may lead to a fire or explosion.
 Squeeze the excess solvent out of the
 element and let dry.
 Do not twist or wring out the foam
   element. This could damage the foam
   material.
 Apply the engine oil.
 Squeeze out the excess oil.
 The element should be wet but not
   dripping.


 More frequent replacement is required when
 riding in unusually dusty or rainy areas.



                                                               Air Cleaner Housing
 AIR CLEANER HOUSING DRAIN
 Remove the drain tube by removing the
 clip.
 Drain the deposits.
 Reinstall the drain tube, securing it with the
 clip.


                                                  Drain Tube                    Clip




3-5