          6. ENGINE REMOVAL                                                           MXU 300/ 250

                                                      Rubber Sleeve                   Nut
 Slide the rubber sleeve back to expose the
 starter motor wire nut.
 Remove the starter motor wire nut for
 disconnect the starter motor wire.




                                                   Ground Wire               Bolt
 Remove the bolt at the starter motor for
 disconnect the ground wire lead.




                                              Ignition Pulse Generator Connector
 Remove the A.C.Generator, ignition pulse
 generator and gear change switch
 connectors.




                                              Gear Change Switch      A.C.Generator Connector
                                              Connectors



                                                                                       6-4