mxu 250 300 2 Werkstatthandbuch : Seite 208

Microfiches
Image preview

Seite 206

Image preview

Seite 207

Image preview

Seite 209

Image preview

Seite 210

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 352
          12. COOLING SYSTEM                                                                             MXU 300/250


 SPECIFICATIONS
                                                      0.75~1.05 kgf/cm
 Radiator cap relief pressure                            (75~105 kPa,
                                                       10.65~14.91 psi)
                        Begins to open                      802
 Thermostat temperature   Full-open                          90
                                                         3.54.5 mm
                                 Valve lift
                                                        (0.140.18 in)
                                                                                Radiator: 110020cc
 Coolant capacity                                Total system 140020cc          Reserve tank: 30020cc

 COOLANT GRAVITY
         Temp. 
 Coolant             0       5        10       15      20      25      30      35      40      45      50
 Concentration
       5%           1.009   1.009   1.008     1.008   1.007   1.006   1.005   1.003   1.001   0.009   0.997
      10%           1.018   1.107   1.017     1.016   1.015   1.014   0.013   1.011   1.009   1.007   1.005
      15%           1.028   1.027   1.026     1.025   1.024   1.022   1.020   1.018   1.016   1.014   1.012
      20%           1.036   1.035   1.034     1.033   1.031   1.029   1.027   1.025   1.023   1.021   1.019
      25%           1.045   1.044   1.043     1.042   1.040   1.038   1.036   1.034   1.031   1.028   1.025
      30%           1.053   1.051   1.051     1.049   1.047   1.045   1.043   1.041   1.038   1.035   1.032
      35%           1.063   1.062   1.060     1.058   1.056   1.054   1.052   1.049   1.046   1.043   1.040
      40%           1.072   1.070   1.068     1.066   1.064   1.062   1.059   1.056   1.053   1.050   1.047
      45%           1.080   1.078   1.076     1.074   1.072   1.069   1.056   1.063   1.062   1.057   1.054
      50%           1.086   1.084   1.082     1.080   1.077   1.074   1.071   1.068   1.065   1.062   1.059
      55%           1.095   1.093   1.091     1.088   1.085   1.082   1.079   1.076   1.073   1.070   1.067
      60%           1.100   1.098   1.095     1.092   1.089   1.086   1.083   1.080   1.077   1.074   1.071

 COOLANT MIXTURE (WITH ANTI-RUST AND ANTI-FREEZING EFFECTS)
   Freezing Point        Mixing Rate       KYMCO SIGMA Coolant Concentrate Distilled Water
      -9                    20%
      -15                   30%                               425cc                            975cc
      -25                   40%
      -37                   50%
      -44.5                 55%

 Cautions for Using Coolant:
 · Use coolant of specified mixing rate. (The mixing rate of 425cc KYMCO SIGMA coolant
   concentrate + 975cc distilled water is 30%.)
 · Do not mix coolant concentrate of different brands.
 · Do not drink the coolant which is poisonous.
 · The freezing point of coolant mixture shall be 5lower than the freezing point of the riding
   area.



                                                                                                       12-2