          16. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                  MXU 300/250


 BATTERY VOLTAGE (OPEN CIRCUIT
 VOLTAGE) INSPECTION
 Remove the seat.
 Disconnect the battery cables.
 Measure the voltage between the battery
 terminals.
 Fully charged : 13.1V
 Undercharged : 12.3V max
 Battery charging inspection must be
   performed with a voltmeter.




 CHARGING
 Connect the charger positive (+) cable to the
 battery positive (+) terminal.
 Connect the charger negative (-) cable to the
 battery negative (-) terminal.
   · Keep flames and sparks away from a
     charging battery.
   · Turn power ON/OFF at the charger, not
     at the battery terminals to prevent
     sparks near the battery to avoid
     explosion.
   · Charge the battery according to the
     current specified on the battery.

 · Quick charging should only be done in
     an emergency.
   · Measure the voltage 30 minutes after
     the battery is charged.
 Charging current: Standard : 1.2A
                    Quick : 3.0A
 Charging time : Standard : 510 hours
                    Quick : 30 minutes
 After charging: Open circuit voltage: 12.8V min.


                                                        16-6