          14. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                 AGILITY CITY 125

 SPECIFICATIONS
                         Item                                          Standard
                       Capacity/Model                 12V-4AH
                       Voltage        Fully charged   13.1V
 Battery               (20)           Undercharged    12.3V
                       Charging current               STD: 0.4A Quick: 4.0A
                       Charging time                  STD: 510hr Quick: 30min
                       Capacity                       0.144KW/5000rpm
 A.C. Generator
                       Charging coil resistance (20) YellowPeach             0.11.0
                       Type                          Single-phase full-wave SCR
 Regulator/Rectifier
                       Limit voltage
                                       Charging       14.50.5V/5000rpm
                       Resistance (20)                5W12
 Resistor


 TORQUE VALUES
 Pulser coil bolt                            0.45~0.6kgf-m
 Stator bolt                                 0.8~1.2kgf-m
 Flywheel nut                                3.5~4.5kgf-m
 Cooling fan bolt                            0.8~1.2kgf-m


 SPECIAL TOOLS
 Universal holder
 Flywheel puller


 TESTING INSTRUMENTS
 Kowa electric tester
 Sanwa electric tester


 TROUBLESHOOTING
 No power                                             Intermittent power
 · Dead battery                                       · Loose battery cable connection
 · Disconnected battery cable                         · Loose charging system connection
 · Fuse burned out                                    · Loose connection or short circuit in
 · Faulty ignition switch                               lighting system

 Low power                                            Charging system failure
 · Weak battery                                       · Loose, broken or shorted wire or connector
 · Loose battery connection                           · Faulty regulator/rectifier
 · Charging system failure                            · Faulty A.C. generator
 · Faulty regulator/rectifier




                                                                                               14-2