          18. BATTERY/CHARGING SYSTEM                                                         MYROAD 700i



 Measure the resistance between each Yellow
 wire terminals.
 Standard: 0.10.5  (20C/68F)

 Check for continuity between each Yellow
 wire terminal of the alternator side connector
 and ground.
 There should be continuity.

 Replace the alternator stator if resistance is
 out of specification, or if any wire has
 continuity to ground.

                                                                             Alternator Connector




 REGULATOR/RECTIFIER                                                        Regulator/Rectifier
 WIRE HARNESS INSPECTION
 Remove the luggage box.

 Disconnect the regulator/rectifier connectors.
 Check the connectors for loose contacts of
 corroded terminals.




                                                          Regulator/Rectifier Connectors
 Battery line
 Measure the voltage between the Red/White
 wire terminal and ground.
 There should be battery voltage at all times.




                                                  Regulator/Rectifier Connector