          11. FUEL SYSTEM                                                    STRYKER 125/150
 AUTO FUEL VALVE
 No Smoking!

  Disconnect the fuel tube and vacuum tube
  from the carburetor.
  Connect a vacuum pump to the vacuum
  tube and apply vacuum. Check if fuel
  flows out.
· The valve is operating normally if fuel
  flows out of the fuel tube when the vacuum
  is applied.                                    Auto Fuel Valve
· The fuel shall stop flowing out when the
  vacuum pump is disconnected.
  If the fuel valve does not operate normally,
  Check the vacuum diaphragm for poor
  installation or damage and inspect the fuel
  tube for clogging.




 INSTALLATION
 Install the fuel tank in the reverse order of
 removal.