          14. BATTERY/CHARGING SYSTEM/
     A.C. GENERATOR                                                       SUPER8 125

 Remove the cooling fan by removing the four
 cooling fan attaching bolts.




                                                                  Cooling Fan
                                               Universal Holder
 Hold the flywheel with an universal holder.
 Remove the flywheel nut.
 Special
 Universal Holder




 Remove the A.C. generator flywheel using
 the flywheel puller.
 Remove the woodruff key.
 Special
 Flywheel Puller




                                                                                Flywheel Puller
                                               A.C. Generator Wire Connector

 Remove the A.C. generator wire connector.