          17. STARTING SYSTEM                                                               ZING125
                                                                  Starter Relay
 STARTER RELAY
 INSPECTION
 Remove the left side cover.
 Turn the ignition switch ON and the starter
 relay is normal if you hear a "click" when
 the starter button is depressed.
 If there is no click sound:
 · Inspect the starter relay voltage
 · Inspect the starter relay ground circuit
 · Check for continuity between the starter
   relay yellow/red and green/red wire                Green/Red              Yellow/Red
   terminals




                                                      Yellow/Red          Green/Red
                                                     Green/Red
 Connect the starter relay yellow/red and
 green/red wires to a 12V battery.
 Connect the starter motor terminals to an
 electric tester and check for continuity
 between the two terminals.
 The relay is normal if there is continuity.
 Replace the starter relay with a new one if
 there is no continuity.



                                                Yellow/Red          Starter Relay


 STARTER MOTOR INSTALLATION
 Apply engine oil to the starter motor O-ring
 and install the starter motor. Install and
 tighten the two mounting bolts.
 Install the starter motor wire lock nut and
 waterproof cover.




                                                                 O-ring

17-5