          15. ELECTRICAL EQUIPMENT                                   AGILITY RS 50 NAKED

                                                                  Starter Relay
 STARTER RELAY INSPECTION
 Remove the foot-floor cover.
 Disconnect the starter relay coupler and
 then remove the starter relay.




 Connect the starter relay (D) terminal to the
 12V battery positive (+) terminal and the
 relay (C) terminal to the battery negative (-)
 terminal. Check for continuity between
 the starter relay (A) and (B) terminals.
 The relay is normal if there is continuity.




 STARTER MOTOR REMOVAL
 Disconnect the starter motor cable.
 Remove the two bolts attaching the starter
 motor and remove the starter motor.
 The installation sequence is the reverse of
 removal.




                                                  Starter Motor



                                                                         15-12