          15. ELECTRICAL EQUIPMENT                                       LIKE 50 2T


 IGNITION COIL INSPECTION
 Continuity Test

   This test is to inspect the continuity of
   ignition coil.

 Remove the met-in box. ( 12)
 Measure the resistance between the
 ignition coil primary coil terminals.
 Resistance (20): 0.1530.187




 Measure the secondary coil resistance
 between the spark plug cap and the primary
 coil terminal as Figure A shown.
 Resistance (20) (with plug cap):
               1014K




 Measure the secondary coil resistance
 between the ignition coil terminal and the
 primary coil terminal as Figure B shown.
 Resistance (20) (without plug cap):
              79K




                                               Ignition Coil