          14. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                               PEOPLE 125/150




             Pulser Coil Set Plate
 Connect the A.C. generator wire connector.      Woodruff Key
 Clean the taper hole in the flywheel off any
 burrs and dirt.
 Install the woodruff key in the crankshaft
 keyway.




                                                            Universal Holder
 Install the flywheel onto the crankshaft with
 the flywheel hole aligned with the crankshaft
 woodruff key.

   The inside of the flywheel is magnetic.
   Make sure that there is no bolt or nut
   before installation.
 Hold the flywheel with the universal holder
 and tighten the flywheel nut.
 Torque: 5.5kg-m
 Special
 Universal Holder
                                                           Cooling Fan

 Install the cooling fan.
 Torque: 0.9kg-m




                                                            Bolts
                                                         Fan Cover
 Install the fan cover.
 Install the rear right side cover. ( 2)