1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          5. FUEL INJECTION SYSTEM                                    MXU 500EXi/MXU500i



 FUEL INJECTOR
 INSPECTION
 Disconnect the fuel injector connector.
 Measure the resistance between 2 pins of the
 fuel injector connector.

 Standard: 10.6~15.9  (at 20°C/68°F)




 REMOVAL
 Disconnect the connector from the fuel
 injector.
 Remove the bolts of the fuel injector.
 Take out of the fuel pipe and fuel injector
 from the Inlet pipe.
 Remove the fuel injector from the fuel pipe.




 
   Ensure the fuel pipe without any             Connector               Bolt
   pressure, then remove the fuel injector.
   STEP 1: Disconnect the fuel pump relay
   or fuel pump connector.
   STEP 2: Turn the key to the ON
   position. Starting the engine till the
   engine stop working.




                                                                         5-22