mxu 550 exi Werkstatthandbuch : Seite 135

Microfiches
Image preview

Seite 133

Image preview

Seite 134

Image preview

Seite 136

Image preview

Seite 137

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          6. COOLING SYSTEM                                                        MXU 550EXi/MXU500i


TORQUE VALUES

Water pump cover bolt                              1.3 kgf-m (13 N-m, 9 lbf-ft)
Fan motor bolt                                     0.53 kgf-m (5 N-m, 3.8 lbf-ft)
Fan motor switch                                   1.8 kgf-m (17 N-m, 13 lbf-ft)




TROUBLESHOOTING

Engine temperature too high
·   Faulty radiator cap
·   Faulty temperature gauge or thermosensor
·   Air in system
·   Thermostat stuck closed
·   Insufficient coolant
·   Passages blocked in radiator, hoses or water jacket
·   Faulty cooling fan motor
·   Faulty fan motor switch
·   Faulty water pump

Engine temperature too low
· Faulty temperature gauge or thermosensor
· Thermostat stuck open
· Faulty fan motor switch

Coolant leak
·   Faulty water pump mechanical seal
·   Deteriorated O-rings
·   Faulty radiator cap
·   Damaged or deteriorated cylinder head gasket
·   Loose hose connection or clamp
·   Damaged or deteriorated hoses




                                                                                      6-4