1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          6. COOLING SYSTEM                                      MXU 550EXi/MXU500i


 COOLING SYSTEM TESTING
                                                  Cap Tester
 RADIATOR CAP INSPECTION

 Remove the radiator cap (refer to the
 "COOLANT REPLACEMENT" section
 in this chapter).

 Pressure testing the radiator cap.
 Replace the radiator cap if it does not hold                  Radiator Cap
 pressure, or if relief pressure is too high or
 too low.
 It must hold the specified pressure for at
 least six seconds.
 Before    installing the cap in the tester,
   wet the sealing surface.
                                                           Cap Tester
 Radiator Cap Relief Pressure:
             90 kPa (0.9 kg/cm, 12.8 psi)

 Pressurize the radiator, engine and hoses,
 and check for leaks.
 Excessive     pressure can damage the
   cooling system components.
   Do not exceed 105 kPa (1.05 kg/cm,
   14.9 psi).
 Repair or replace components if the system
 will not hold the specified pressure for at
 least six seconds.

 COOLANT REPLACEMENT

 PREPARATION

  The effectiveness of coolant decreases
  with the accumulation of rest or if there is
  a change in the mixing proportion during
  usage. Therefore, for best performance
  change the coolant regularly as specified
  in he maintenance schedule.
  Mix only distilled, low mineral water
  with the antifreeze.

 Recommended mixture:
       1:1 (Distilled water and antifreeze)

6-5