1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          6. COOLING SYSTEM                                                  MXU 550EXi/MXU500i


 Place the machine on a flat, level surface.    Reserve Tank Cap
 Fill the reserve tank to the upper level
 (FULL) line.




                                                                      Filler Neck
 Fill the system with the recommended
 coolant through the filler opening up to the
 filler neck.




 Bleed air from the system as follow:
 1. Start the engine and let it idle for 2-3
    minutes.
 2. Snap the throttle three to four times to
    bleed air from the system.
 3. Stop the engine and add coolant to the
    proper level if necessary. Reinstall the
    radiator cap.
 4. Check the level of coolant in the reserve
    tank and fill to the upper level if it is
    low.




6-7