1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          17. BATTERY/CHARGING SYSTEM                      MXU 550EXI/MXU500I


 CHARGING VOLTAGE INSPECTION

 Be sure that the battery is in good condition
 before performing this test.

 Do not disconnect the battery or any
   cable in the charging system without
   first switching off the ignition switch.
   Failure to follow this precaution can
   damage the tester or electrical
   components.
 Start the engine and warm it up to the
 operating temperature; stop the engine.
 Connect the multi-meter between the positive
 and negative terminals of the battery.

 To prevent short, make absolutely certain
 which are the positive and negative terminals
 or cable.
 With the headlight on and turned to the high
 beam position, restart the engine.
 Measure the voltage on the multi-meter when
 the engine runs at 5000 min (rpm).

 Standard:
 14.01.0V / 5000 rpm




 ALTERNATOR CHARGING COIL

 INSPECTION

 Disconnect the alternator connector.




                                                     Alternator Connector


                                                                      17-6