1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          6. COOLING SYSTEM                                                MXU 550EXi/MXU500i


 Install the water pump cover and tighten the
 bolts to the specified toque.

 Torque: 1.3 kgf-m (13 N-m, 9 lbf-ft)




                                                Water Pump Cover/O-ring


                                                                           Water Hose

 Connect the water hoses and bypass hose,
 then tighten the hose bands.

 Fill the system with recommended coolant
 and bleed the air (refer to the "COOLANT
 REPLACEMENT" section in this
 chapter).




                                                       Water Hose         Bypass Hose




6-13