17. IGNITION SYSTEM SERVICE INFORMATION GENERAL INSTRUCTIONS · Check the ignition system according to the sequence specified in the Troubleshooting. ( 1-28) · The ignition system adopts CDI unit and the ignition timing cannot be adjusted. · If the timing is incorrect, inspect the CDI unit and A.C. generator and replace any faulty parts. Inspect the CDI unit with a CDI tester · Loose connector and poor wire connection are the main causes of faulty ignition system. Check each connector before operation. · Use of spark plug with improper heat range is the main cause of poor engine performance. · The inspections in this section are focused on maximum voltage. The inspection of ignition coil resistance is also described in this section. · Inspect the ignition switch according to the continuity table specified in page 20-3. · Inspect the spark plug referring to Section 3. · Remove the A.C. generator and pulser coil referring to Section 10. SPECIFICATIONS Item Standard SH10BA BR8HSA Spark plug SH10AA BR6HSA Spark plug gap 0.81.0mm Ignition timing 13.5°2°BTC/2000rpm Primary coil 0.1530.187 Ignition coil resistance (20) Secondary without plug cap 3.243.96K coil with plug cap 6.9910.21K Pulser coil resistance (20) 50170 Exciter coil resistance (20) 50350 Ignition coil primary side max. voltage 244V Pulser coil max. voltage 10.5V Exciter coil max. voltage 244V TESTING INSTRUMENT Electric tester TROUBLESHOOTING No spark at plug Engine starts but turns poorly · Faulty spark plug · Ignition primary circuit · Poorly connected, broken or shorted wire --Faulty ignition coil · Faulty ignition switch --Poorly connected wire or connector · Faulty ignition coil --Poorly contacted ignition switch · Faulty CDI unit · Ignition secondary circuit · Faulty A.C. generator --Faulty ignition coil --Faulty spark plug --Faulty high-tension wire --Poorly insulated plug cap · Improper ignition timing --Faulty A.C. generator --Stator not installed properly --Faulty CDI unit 17-2