dink 50 125 1 Werkstatthandbuch : Seite 385

Microfiches
Image preview

Seite 383

Image preview

Seite 384

Image preview

Seite 386

Image preview

Seite 387

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 424
          16. BATTERY/CHARGING SYSTEM                      DINK50/ 125




 REGULATOR/RECTIFIER

 WIRE HARNESS INSPECTION

 Remove the luggage box (refer to the
 "FRAME COVERS
 REMOVAL/INSTALLATION" section in
 the chapter 2).

 Disconnect the regulator/rectifier connectors
 (1).
 Check the connectors for loose contacts of
 corroded terminals.




 Battery line

 Measure the voltage between the Red/White
 wire terminal and ground.
 There should be battery voltage at all times.




 Ground line

 Check the continuity between the Green wire
 terminal and ground.
 There should be continuity at all times.