          12. COOLING SYSTEM                                                     ATV 300/250


 COOLING SYSTEM TESTING                                             Radiator Cap
 RADIATOR CAP INSPECTION

 Remove the radiator cap from the coolant
 filler hose.




 Install the radiator cap onto the radiator
 tester and apply specified pressure to it. It
 must hold specified pressure for at least six   Radiator Tester
 seconds.
 Apply water to the cap sealing surface
   before testing.
 Radiator Cap Relief Pressure:
 0.75~1.05 kgf/cm (75~105 kPa,
 10.65~14.91 psi)
                                                                   Radiator Cap




 Install the radiator tester onto the radiator
 and apply specified pressure to it. It must
 hold specified pressure for at least six
 seconds.
 Check the water hoses and connectors for
 leaks.
 The test pressure should not exceed 1.05
   kg/cm (105 kPa, 14.91 psi). Excessive
   pressure can damage the radiator and its
   hose connectors.




12-3