spacer 50 125 1 Werkstatthandbuch : Seite 212

Microfiches
Image preview

Seite 210

Image preview

Seite 211

Image preview

Seite 213

Image preview

Seite 214

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 232
          19. SWITCHES/HORN/FUEL UNIT/THERMOSTATIC SWITCH
    /TEMPERATURE GAUGE/INSTRUMENTS/LIGHTS
                                                                 12V Battery
 HORN INSPECTION
 Remove the front upper cover. ( 2-5)
 Disconnect the horn wire couplers.
 The horn is normal if it sounds when a 12V
 battery is connected across the horn wire
 terminals.




                                                              Horn
 FUEL UNIT
 FUEL UNIT INSPECTION
 Remove the fuel unit.
 Disconnect the fuel unit wire connectors.
 Measure the resistance between the fuel unit                 Upper
 wire terminals with the float at upper and
 lower positions.
                                                 Upper
  Wire Terminals      Upper          Lower                   Lower
     Y/WG            3345          500850
     L/WG          400700 100200                 Lower
   Y/WL/W          450750 450750

                                                 Fuel Unit
 FUEL GAUGE INSPECTION
 Connect the fuel unit wire connectors and
 turn the ignition switch "ON".
 Before performing the following test,            Upper
    operate the turn signals to determine that
    the battery circuit is normal.
 Check the fuel gauge needle for correct
 indication by moving the fuel unit float up
 and down.
     Float Position        Needle Position                           Fuel Gauge

        Upper                "F" (Full)
        Lower               "E" (Empty)

    Wire Terminals         Needle Position
      Y/WG                  From E to F
      L/WG                  From F to E
 The fuel gauge is normal if it operates as
 above indicated. If not, check for loosely          Lower
 tightened nuts, poorly connected terminals or
 shorted wires.
                                                               Needle moves
                                                               from F to E.

19-5